Erratum to “Characterization of a 1 mm (DC to 110 GHz) Calibration Kit for VNA”

Article information

J. Electromagn. Eng. Sci. 2021;21(2):165-165
Publication date (electronic) : 2021 April 30
doi : https://doi.org/10.26866/jees.2021.21.2.e
Group for Electromagnetic Wave Metrology, Division of Physical Metrology, Korea Research Institute of Standards and Science, Daejeon, Korea
*Corresponding Author: Chihyun Cho (e-mail: chihyun.cho@kriss.re.kr)
This corrects the article "Characterization of a 1 mm (DC to 110 GHz) Calibration Kit for VNA" in Volume 19 on page 272.

In the paper entitled “Characterization of a 1 mm (DC to 110 GHz) Calibration Kit for VNA (Journal of Electromagnetic Engineering and Science, vol. 19, no. 4, pp. 272–278, 2019)”, a typographical error occurred in Equation (7). The correct equation follows:

(7) Ri=ωLi=(1πd+1πD)ωμ0μr2σ

Article information Continued